SciELO - Scientific Electronic Library Online

 
vol.43 número3Biological sulphate reduction with primary sewage sludge in an upflow anaerobic sludge bed reactor - Part 5: Steady-state modelEvaluation of oxidising disinfectants to control Vibrio biofilms in treated seawater used for fish processing índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Water SA

versão On-line ISSN 1816-7950
versão impressa ISSN 0378-4738

Resumo

DE OLIVEIRA, Danieli Soares  e  TEIXEIRA, Edmilson Costa. Experimental evaluation of helically coiled tube flocculators for turbidity removal in drinking water treatment units. Water SA [online]. 2017, vol.43, n.3, pp.378-386. ISSN 1816-7950.  http://dx.doi.org/10.4314/wsa.v43i3.02.

The constant need to improve water treatment techniques allows for the emergence of new technologies for obtaining adequate water, both in terms of quality and quantity. In order to obtain an efficient, rapid and low-cost clarification system, this study proposes the use of helically coiled tubes (HCTs) as a coagulation-flocculation reactor coupled with a conventional decanter system. Eighty-four (84) turbidity removal tests were performed to evaluate the proposed clarification system, while varying hydraulic and geometrical parameters in HCTs. Removal efficiency values higher than 80% were obtained (with a maximum removal efficiency of 86.2%), presenting better results than systems using baffled tanks, which are traditionally applied for water treatment purposes in developing countries. In addition, significantly lower processing times (lower than 2 min, about 10% of baffled tank processing times) were observed for high efficiency process values, indicating that this clarification system can be useful in rational design of coagulation-flocculation units. It should be noted that the turbidity removal efficiency results obtained (with a rising-then-decreasing behaviour over time) differ significantly from those obtained by the commonly used models for flocculation evaluation (with asymptotic behaviour over time), presenting a maximum absolute percentage deviation of 48.9%, and indicating caution in the use of such models for alternative flocculation unit evaluation.

Palavras-chave : flocculation; drinking water; turbidity; turbidity removal efficiency; helically coiled tubes.

        · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons