Services on Demand
Article
Indicators
Related links
- Cited by Google
- Similars in Google
Share
Water SA
On-line version ISSN 1816-7950
Print version ISSN 0378-4738
Abstract
HUBERT, Elena and WOLKERSDORFER, Christian. Establishing a conversion factor between electrical conductivity and total dissolved solids in South African mine waters. Water SA [online]. 2015, vol.41, n.4, pp.490-500. ISSN 1816-7950. http://dx.doi.org/10.4314/WSA.V41I4.08.
Total dissolved solids (TDS, in mg/ℓ) can be estimated from measurements of electrical conductivity at 25°C (EC, in μS/cm) by applying a conversion factor f. This factor is commonly reported to range from 0.54 to 1.1. For 45 South African mine-water samples, factors between 0.25 and 1.34, with a median of 0.85, were determined. The samples cover an EC-range of 70- 16 000 μS/cm and TDS of 50-14 000 mg/ℓ. Linear regression for the entire dataset yields a conversion factor of 0.88 but for samples with EC < 5 000 μS/cm, a conversion factor of 0.97 is recommended. However, both of these factors allow only estimates of TDS and for accurate TDS values it is necessary to determine the conversion factor specifically for each site. Besides spatial variations, temporal variations of conversion factors were also observed.
Keywords : EC; electrical conductivity; mine water; TDS; total dissolved solids; SA; South Africa.