vol.19 número4Fixation of femoral neck fractures in patients younger than 65 years: a retrospective descriptive study at a high-volume trauma centreAn intra-operative device for parallel drilling and femoral landmark estimation during medial patellofemoral ligament reconstructive surgery índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • En proceso de indezaciónSimilares en Google

Compartir


SA Orthopaedic Journal

versión On-line ISSN 2309-8309
versión impresa ISSN 1681-150X

Resumen

MOONDA, Z; NORTJE, MB  y  DEY, R. Does the intra-operatively measured leg length correction compare to the post-operative radiograph in total hip replacement surgery?. SA orthop. j. [online]. 2020, vol.19, n.4, pp.206-211. ISSN 2309-8309.  http://dx.doi.org/10.17159/2309-8309/2020/v19n4a2.

BACKGROUND: This study aims to analyse the accuracy of the Vertical Measurement System™ (VMS) in assessing the leg length correction (LLC) during total hip arthroplasty (THA) by comparing the intra-operative measurements to the radiographic measurements obtained six weeks post-operatively Patients and methods: A prospective cohort study was conducted in which patients undergoing primary THA were enrolled at two centres in Cape Town, over a period of 19 weeks. THAs were performed by four surgeons. Pre-operative leg length discrepancy (LLD) measurements were obtained in 92 patients. The VMS was used to predict intra-operative LLC, and this measurement was compared to the post-operative LLC measured on the six-week follow-up X-ray. These measurements were statistically compared using the Mann-Whitney U test. RESULTS: The difference between the intra-operative VMS calculation and the six-week radiological measurement was not significant (p>0.05), with the difference in their mean values being 0.1±3.3 mm. In the cohort, 82% of the patients (n=75) were within 5 mm of the target LLC, and 96% of patients (n=88) were within 10 mm of the target LLC. The mean absolute residual LLD at six weeks was 3.2±3.1 mm. CONCLUSION: The intra-operative LLC measurement obtained using the VMS accurately predicts the six-week post-operative radiographic LLC measurement Level of evidence: Level 4

Palabras clave : total hip replacement; leg length discrepancy; leg length correction; vertical measurement system; comparative study; longitudinal study.