SciELO - Scientific Electronic Library Online

 
vol.13 número4Occipito-cervical fusion: review of surgical indications, techniques and clinical outcomes índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Em processo de indexaçãoSimilares em Google

Compartilhar


SA Orthopaedic Journal

versão On-line ISSN 2309-8309
versão impressa ISSN 1681-150X

Resumo

NAUDE, PH; ROCHE, S; NORTJE, M  e  MAQUNGO, S. The safety and efficacy of percutaneous sacroiliac joint screw fixation. SA orthop. j. [online]. 2014, vol.13, n.4, pp.26-29. ISSN 2309-8309.

PURPOSE OF STUDY: Percutaneous screw fixation of sacroiliac joint dislocations, fracture-dislocations and sacral fractures is a well-recognised technique first described by Routt and has increasingly gained popularity in recent times. This method is biomechanically comparable to open reduction and internal fixation with plates and screws but offers the advantages of minimally invasive surgical techniques. It is however a technically demanding procedure with reported complications including hardware failure, misplacement of screws, nerve injury and poor posterior reduction. The purpose of the study is to report clinical and radiological results of patients treated with closed reduction and percutaneous iliosacral screw fixation for unstable pelvic ring fractures. METHODS: A retrospective review of clinical notes and radiological studies was performed on all patients who had percutaneous sacroiliac fixation between 2009 and 2012. Forty-five percutaneous sacroiliac screws were inserted in 41 patients with a mean age of 25.6 years (range 17-62). Fracture types included 15 AO type B, and 26 AO type C. RESULTS: All patients had a satisfactory initial reduction. One patient (2.4%) had screw misplacement with resultant temporary neurological fallout. One patient (2.4%) had screw misplacement without neurological fallout. Both these patients initially had two screws inserted and the misplaced screws were removed and not resited. One patient (2.4%) had screw cut-out with loss of reduction. This screw was removed, open reduction performed, and the screw was reinserted. CONCLUSION: The use of percutaneous sacroiliac screws provides a safe and effective technique for the management of unstable posterior pelvic ring injuries. Our combined complication rate compares favourably with published literature.

Palavras-chave : unstable pelvic ring injuries; percutaneous sacroiliac fixation; pelvis fracture fixation.

        · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons