vol.38 número1Torsade de pointes caused by hydroxychloroquine use in a patient with a severe form of COVID-19Variation in timing of decisions to withdraw life-sustaining treatment in adult ICU patients from three centres in different geographies: Do clinical factors explain the difference? índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Southern African Journal of Critical Care (Online)

versão On-line ISSN 2078-676X
versão impressa ISSN 1562-8264

Resumo

KUBA, M-C F; SALIE, S  e  MORROW, B M. Risk factors and outcomes of extubation failure in a South African tertiary paediatric intensive care unit. South. Afr. j. crit. care (Online) [online]. 2022, vol.38, n.1, pp.26-32. ISSN 2078-676X.  http://dx.doi.org/10.7196/SAJCC.2022.v38i1.513.

BACKGROUND. Extubation failure contributes to poor outcome of mechanically ventilated children, yet the prevalence and risk factors have been poorly studied in South African (SA) children. OBJECTIVE. To determine the prevalence, risk factors and outcomes of extubation failure in an SA paediatric intensive care unit (PICU). METHODS. This was a prospective, observational study of all mechanically ventilated children admitted to a tertiary PICU in Cape Town, SA. Extubation failure was defined as requiring re-intubation within 48 hours of planned extubation. RESULTS. There were 219 episodes of mechanical ventilation in 204 children (median (interquartile range (IQR)) age 8 (1.6 - 44.4) months). Twenty-one of 184 (11.4%) planned extubations (95% confidence interval (CI) 7.2% - 16.9%) failed. Emergency cardiac admissions (adjusted odds ratio (aOR) 7.58 (95% CI 1.90 - 30.29), dysmorphology (aOR 4.90; 95% CI 1.49 - 16.14), prematurity (aOR 4.39; 95% CI 1.24 - 15.57), and ventilation >48 hours (aOR 6.42 (95% CI 1.57 - 26.22) were associated with extubation failure. Children who failed extubation had longer durations of ventilation (231 hours (146.0 - 341.0) v. 53 hours (21.7 - 123.0); p<0.0001); longer duration of PICU (15 (9 - 20) days v. 5 (2 - 9) days; p<0.0001) and hospital length of stay (32 (21 - 53) days v. 15 (8 - 27) days; p=0.009); and higher 30-day mortality (28.6% v. 6.7%; p=0.001) than successfully extubated children. CONCLUSIONS. Extubation failure was associated with significant morbidity and mortality in our setting. Risk factors for extubation failure identified in our context were similar to those reported in other settings.

Palavras-chave : intubation; extubation failure; risk factors; paediatric intensive care unit; mechanical ventilation; outcomes.