SciELO - Scientific Electronic Library Online

 
vol.33 issue1 author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Article

Indicators

Related links

  • On index processCited by Google
  • On index processSimilars in Google

Share


Southern African Journal of Critical Care (Online)

On-line version ISSN 2078-676X
Print version ISSN 1562-8264

Abstract

WISE, R D et al. Correlation between different methods of intra-abdominal pressure monitoring in varying intra-abdominal hypertension models. South. Afr. j. crit. care (Online) [online]. 2017, vol.33, n.1, pp.15-18. ISSN 2078-676X.  http://dx.doi.org/10.7196/SAJCC.2017.v33i1.327.

BACKGROUND. Advances in intra-abdominal pressure (IAP) measurement have enabled better monitoring and physiological manipulation of patients with intra-abdominal hypertension or abdominal compartment syndrome. This study aimed to determine the correlation between transvesical (TV), transgastric (TG) and direct transperitoneal (TP) IAP monitoring at different IAPs in porcine models. OBJECTIVES. To assess the statistical agreement between TV, TG and TP pressure monitoring in a pneumoperitoneum and an intestinal obstruction intra-abdominal hypertension model at different IAPs. METHODS. Fifty-nine pigs were divided into six groups: a control group (Cr; n=5), three pneumoperitoneum groups at pressures of 20 mmHg, 30 mmHg, and 40 mmHg (Pn20, Pn30, Pn40; n=40), and two intestinal-occlusion groups at pressures of 20 mmHg and 30 mmHg (Oc20, Oc30; n=14). IAP was simultaneously measured in each pig using the three methods at different times. The control group did not have any intervention to increase the IAP. Intra-class correlation was used to assess agreement between the methods. RESULTS. At pressures >20 mmHg, all three methods showed good correlation with each other (Pn20=0.87; Pn30=0.96; Pn40=0.88; Oc20=0.69; Oc30=0.86). Correlation between TP and TG (Cr=0.0; Pn20=0.85; Pn30=0.94; Pn40=0.90; Oc20=0.78; Oc30=0.78); TP and TV (Cr=0.0; Pn20=0.83; Pn30=0.95; Pn40=0.86; Oc20=0.59; Oc30=0.88); and importantly between TV and TG (Cr=0.0; Pn20=0.95; Pn30=0.98; Pn40=0.88; Oc20=0.69; Oc30=0.91) was good. CONCLUSION. All three measurement methods showed good correlation at pressures >20 mmHg and were unaffected by the type of IAP model. These results suggest that either transvesical or transgastric pressure measurements can be used for IAP measurement when TP pressures are >20 mmHg.

        · text in English     · English ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License