SciELO - Scientific Electronic Library Online

 
vol.85 issue1Retrospective study on the incidence of Salmonella isolations in animals in South Africa, 1996 to 2006Seroprevalence of bovine brucellosis in trade cattle slaughtered in Ibadan, Nigeria, from 2004-2006 author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Article

Indicators

Related links

  • On index processCited by Google
  • On index processSimilars in Google

Share


Journal of the South African Veterinary Association

On-line version ISSN 2224-9435
Print version ISSN 1019-9128

Abstract

BUYS, Angela; MACDONALD, Raynard; CRAFFORD, Jannie  and  THERON, Jacques. Development of a flow cytometric bead immunoassay and its assessment as a possible aid to potency evaluation of enterotoxaemia vaccines. J. S. Afr. Vet. Assoc. [online]. 2014, vol.85, n.1, pp.01-06. ISSN 2224-9435.

Enterotoxaemia, an economically important disease of sheep, goats and calves, is caused by systemic effects of the epsilon toxin produced by the anaerobic bacterium Clostridium perfringens type D. The only practical means of controlling the occurrence of enterotoxaemia is to immunise animals by vaccination. The vaccine is prepared by deriving a toxoid from the bacterial culture filtrate and the potency of the vaccine is tested with the in vivo mouse neutralisation test (MNT). Due to ethical, economic and technical reasons, alternative in vitro assays are needed. In this study an indirect cytometric bead immunoassay (I-CBA) was developed for use in vaccine potency testing and the results were compared with those obtained using an indirect enzyme-linked immunosorbent assay (I-ELISA) and the MNT. Sera were collected from guinea pigs immunised with three different production batches of enterotoxaemia vaccine and the levels of anti-epsilon toxin antibodies were determined. Although the intra- and inter-assay variability was satisfactory, epsilon antitoxin levels determined by both the I-ELISA and indirect cytometric bead immunoassay (I-CBA) tests were higher than those of the MNT assay. In contrast to the MNT, all of the serum samples were identified as having antitoxin levels above the required minimum (not less than 5 U/mL). These results indicate that the respective in vitro tests in their current formats are not yet suitable alternatives to the in vivo MNT. The growing demand for a more humane, cost-effective and efficient method for testing the potency of enterotoxaemia vaccines, however, provides a strong impetus for further optimisation and standardisation of the I-CBA assay but further analytical research is required.

        · text in English     · English ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License