SciELO - Scientific Electronic Library Online

 
vol.76Flower of Typha latifolia as a Low-cost Adsorbent for Quantitative Uptake of Multiclass Pesticide Residues from Contaminated WatersUltrasound Promoted Stereoselective Synthesis of 2,3-Dihydrobenzofuran Appended Chalcones at Ambient Temperature índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Em processo de indexaçãoSimilares em Google

Compartilhar


South African Journal of Chemistry

versão On-line ISSN 1996-840X
versão impressa ISSN 0379-4350

Resumo

SSENGOOBA, Frank et al. Comparison of laser nephelometric and HPLC techniques for efficient determination of solubility of ibuprofen and its 2-hydroxypropyl-β-cyclodextrin inclusion complex. S.Afr.j.chem. (Online) [online]. 2022, vol.76, pp.49-55. ISSN 1996-840X.  http://dx.doi.org/10.17159/0379-4350/2022/v76a08.

Poor drug solubility is a major problem that hinders the discovery and development of new drugs. There is a need for rapid and inexpensive techniques for acquiring reliable drug solubility data. In this study, the suitability of laser nephelometry for the determination of solubility was investigated using ibuprofen, as a model drug of low solubility, and its 2-hydroxypropyl-p-cyclodextrin inclusion complex (ic). This investigation involved the preparation of ibuprofen-ic-cyclodextrin (1:1) using coprecipitation and characterisation. Thermal analysis and assessment of molecular vibrations confirmed the existence of the inclusion complex. The shake flask testing method was employed and carried out in acidic and alkaline media, and solubility data were verified against high-performance liquid chromatography (HPLC). Results obtained via nephelometry showed relative enhanced solubility of ibuprofen in both acidic (0.565 mg ml-1) and basic (7.5 mg ml-1) media, respectively, which was enabled via inclusion complex formation. Relative to nephelometry data, HPLC results showed a similar trend with increased solubility values in acidic (0.454 mg ml-1) and basic (201.73 mg ml-1) media, respectively. The application of laser nephelometry proved to be a quick and relatively cost-effective technique for solubility measurements of the parent drug and its carrier system.

Palavras-chave : cyclodextrin; ibuprofen; inclusion complex; laser nephelometry; solubility.

        · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons