SciELO - Scientific Electronic Library Online

 
vol.63The oxidation of rhenium(III) by dioxygen in the presence of tri- and tetradentate N,O-donor ligandsSynthesis of nitrogen-doped carbon nanotubes with layered double hydroxides containing iron, cobalt or nickel as catalyst precursors author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Article

Indicators

Related links

  • On index processCited by Google
  • On index processSimilars in Google

Share


South African Journal of Chemistry

On-line version ISSN 1996-840X
Print version ISSN 0379-4350

Abstract

KATSKOV, Dimitri A.  and  KHANYE, G. Eunice. Simultaneous multi-element electrothermal atomic absorption determination using a low resolution CCD spectrometer and continuum light source: The concept and methodology. S.Afr.j.chem. (Online) [online]. 2010, vol.63, pp.45-57. ISSN 1996-840X.

A low resolution CCD spectrometer with continuum light source and fast-heated graphite tube atomizer was employed for simultaneous multi-element determination by electrothermal atomic absorption spectrometry (SMET AAS). The sample vaporization pulse was monitored by fast scanning of vapour spectra within the 190-410 nm wavelength range; absorption was measured at the CCD pixels corresponding to atomic resonance lines; function absorbance vs. concentration of atomic vapour was automatically linearized, and the modified signals integrated. The setup consisted of a D2 or Xe arc lamp, a spectral instrument with a half-width of transmittance profile 120 pm, a linear CCD array attached to a PC and a tube atomizer furnished with a carbon fibre collector. In the experiments simultaneous determination of 18 elements was performed in the mixed solutions at the mg L-1 to L-1 level, within 4-4.5 orders of magnitude linear concentration range. About 1-2 min was needed for the measurement and calculation. Limits of detection (LOD) for individual elements were 1.5-2 orders of magnitude higher than those in the single element ET AAS, but similar or below those in flame AAS. Further reduction of LODs and correction of possible spectral and chemical interferences are associated with optimization of the light source and atomization programme and modification of the calculation algorithm.

Keywords : Electrothermal atomic absorption spectrometry; simultaneous multi-element determination; CCD spectrometer; fast-heated graphite tube atomizer.

        · text in English     · English ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License