SciELO - Scientific Electronic Library Online

 
vol.107 número7Snakebite: admissions at a tertiary health care centre in Maharashtra, India índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • En proceso de indezaciónSimilares en Google

Compartir


SAMJ: South African Medical Journal

versión On-line ISSN 2078-5135
versión impresa ISSN 0256-9574

Resumen

JONES, G W; SAMUEL, R A  y  BICCARD, B M. Management of failed spinal anaesthesia for caesarean section. SAMJ, S. Afr. med. j. [online]. 2017, vol.107, n.7, pp.611-614. ISSN 2078-5135.  http://dx.doi.org/10.7196/samj.2017.v107i7.12056.

BACKGROUND. Failed spinal anaesthesia for caesarean section (CS) may be partial or complete and the subsequent discomfort is the most commonly cited cause of litigation in obstetric anaesthesia. OBJECTIVES. To determine if there is a standardised approach to: (i) testing the level of block of spinal anaesthesia; and (ii) the management of failed spinal anaesthesia for CS. METHODS. A structured questionnaire to ascertain the current practice of testing the level of block and management of three different scenarios of failed spinal anaesthesia was distributed to 51 government hospitals in KwaZulu-Natal, South Africa (SA). All obstetric anaesthetic service providers, ranging from interns to specialist anaesthetists, were invited to complete the questionnaire. RESULTS. A total of 375 responses were received from 42 of the 51 hospitals surveyed. Specialist anaesthetists managed failure of spinal anaesthesia significantly differently than other anaesthetic service providers. Specialists were more likely to convert to a general anaesthetic (GA), while others were more likely to repeat spinal anaesthesia or administer intravenous ketamine, midazolam and opioids. Only 212 respondents (56%) tested the level of block and there was no difference between the groups with regard to the method of assessment of height (p=0.15). Non-specialists, however, accepted a significantly lower level of block, using pinprick, than specialists (p=0.027), which could lead to a higher failure rate. More than one-third of non-specialists did not consider themselves competent to perform a GA and >90% of respondents agreed that a 'failed' spinal algorithm would be useful. CONCLUSION. There is a need for standardised assessment of the adequacy of spinal anaesthesia for CS in SA, as well as a failed spinal algorithm.

        · texto en Inglés     · Inglés ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons