SciELO - Scientific Electronic Library Online

 
vol.109 número2FAST scanning in the developing world emergency department índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

    Links relacionados

    • Em processo de indexaçãoCitado por Google
    • Em processo de indexaçãoSimilares em Google

    Compartilhar


    SAMJ: South African Medical Journal

    versão On-line ISSN 2078-5135versão impressa ISSN 0256-9574

    Resumo

    PILLAY, S; ALDOUS, C M; SINGH, D  e  PILLAY, D. Validation and effect on diabetes control of glycated haemoglobin (HbA1c) point-of-care testing. SAMJ, S. Afr. med. j. [online]. 2019, vol.109, n.2, pp.112-115. ISSN 2078-5135.  https://doi.org/10.7196/samj.2019.v109i2.13447.

    BACKGROUND: Optimal control of diabetes mellitus (DM) remains daunting globally. Point-of-care testing (POCT) for glycated haemoglobin (HbAlc) enables the clinician to make immediate management decisions and thereby improve DM control and complications. Better control is increasingly being striven for in developing countries where availability of POCT devices is limitedMETHODS: Every alternate patient who visited the diabetes clinic at Edendale Hospital, Durban, South Africa, between 1 June 2017 and 31 August 2017 was invited to participate in the study. These patients made up the POCT group, with the remainder making up the control laboratory group. The POCT group had Quo-Test HbAlc POCT done at the clinic visit and their treatment was adjusted based on the HbAlc reading, while the control group received standard treatment. The two groups of patients were reviewed at 3 months to identify differences in diabetes control between themRESULTS: Data from 266 patients were analysed (135 in the POCT group v. 131 in the control group). There was no significant difference between the price of the POCT and laboratory HbAlc tests (p=0.823). The POCT and laboratory HbAlc values showed good correlation at baseline (r=0.995; p<0.001). The two groups of patients were evenly matched in respect of most demographic and clinical variables. Patients in the POCT group showed a significant improvement in mean (standard deviation) glycaemic control between baseline and 3 months (9.61 (2.46) v. 8.98 (2.15); p<0.043). No improvement was noted in the control group (9.58 (2.49) v. 9.43 (2.15);p=0.823CONCLUSIONS: The Quo-Test HbAlc POCT had good correlation with standard laboratory methods in respect of both glycaemic control and price. Patients who had POCT at baseline showed a significant improvement in glycaemic control at 3 months. HbAlc POCT in the setting of a multifaceted approach to diabetes care has been shown to have definite benefits

            · texto em Inglês     · Inglês ( pdf )